HP2 - HPE DL360 Gen10

HP2 - HPE DL360 Gen10#

Asset Summary#

Field Details
Manufacturer HPE
Model DL360 Gen10
Hostname HP2Proxmox
Management address 10.1.1.12
iLO address 10.1.5.12
iLO hostname HP2-iLO
iLO firmware 3.15 (2025-08-11)
Serial number MXQ9510448
Product number P19775-B21
Physical location Server Rack

Server Chassis#

Field Details
Form factor Rack-mount server
Rack height 1U
Chassis configuration HPE ProLiant DL360 Gen10
System board HPE ProLiant DL360 Gen10; board serial PXAQA0ARHD006W
Drive-bay configuration
Rail kit HP rails
Other chassis components

Processors#

Socket Manufacturer Model Cores Threads Speed Serial/identifier Notes
CPU 1 Intel Xeon Gold 6138 20 40 2.00 GHz
CPU 2 Intel Xeon Gold 6138 20 40 2.00 GHz

Memory#

Slot Manufacturer Part number Type Capacity Speed ECC Serial number Notes
PROC 1 DIMM 1 RDIMM 32 GiB 2400 MHz ECC
PROC 1 DIMM 2 RDIMM 32 GiB 2400 MHz ECC
PROC 1 DIMM 3 RDIMM 32 GiB 2400 MHz ECC
PROC 1 DIMM 4 RDIMM 32 GiB 2400 MHz ECC
PROC 1 DIMM 5 RDIMM 32 GiB 2400 MHz ECC
PROC 1 DIMM 6 RDIMM 32 GiB 2400 MHz ECC
PROC 1 DIMM 7 RDIMM 32 GiB 2400 MHz ECC
PROC 1 DIMM 8 RDIMM 32 GiB 2400 MHz ECC
PROC 1 DIMM 9 RDIMM 32 GiB 2400 MHz ECC
PROC 1 DIMM 10 RDIMM 32 GiB 2400 MHz ECC
PROC 1 DIMM 11 RDIMM 32 GiB 2400 MHz ECC
PROC 1 DIMM 12 RDIMM 32 GiB 2400 MHz ECC
PROC 2 DIMM 1 RDIMM 32 GiB 2400 MHz ECC
PROC 2 DIMM 2 RDIMM 32 GiB 2400 MHz ECC
PROC 2 DIMM 3 RDIMM 32 GiB 2400 MHz ECC
PROC 2 DIMM 4 RDIMM 32 GiB 2400 MHz ECC
PROC 2 DIMM 5 RDIMM 32 GiB 2400 MHz ECC
PROC 2 DIMM 6 RDIMM 32 GiB 2400 MHz ECC
PROC 2 DIMM 7 RDIMM 32 GiB 2400 MHz ECC
PROC 2 DIMM 8 RDIMM 32 GiB 2400 MHz ECC
PROC 2 DIMM 9 RDIMM 32 GiB 2400 MHz ECC
PROC 2 DIMM 10 RDIMM 32 GiB 2400 MHz ECC
PROC 2 DIMM 11 RDIMM 32 GiB 2400 MHz ECC
PROC 2 DIMM 12 RDIMM 32 GiB 2400 MHz ECC

Storage Drives#

Bay/slot Manufacturer Model Drive type Interface Capacity Serial number Firmware Notes
Drive bay Patriot P210 1TB SSD SATA 1 TB P210HBCB230711000902
Drive bay X356 X356_S16333T8ATE SSD SAS 3.5 TB S2JVNAAH613856
Drive bay SPCC Solid State Disk SSD SAS 1 TB A20231231S301KG13068
Drive bay Samsung SSD 860 QVO 1TB SSD SAS 1 TB S59HNG0N300017Z
Drive bay Patriot P210 1TB SSD SAS 1 TB P210HBCB230711000653
Drive bay P5V800GD EMC800 SSD SAS 800 GB Z940A00DT16R
Drive bay P5V800GD EMC800 SSD SAS 800 GB Z920A015T16R
Drive bay P5V800GD EMC800 SSD SAS 800 GB Z940A002T16R
Drive bay P5V800GD EMC800 SSD SAS 800 GB Z920A01LT16R
External/removable Netac NetacPortableSSD External SSD USB 512 GB AA20230614512GB05261
PCIe NVMe 1 Samsung 990 EVO 1TB NVMe SSD NVMe 1 TB S7M3NS0X520060N
PCIe NVMe 2 Samsung 990 EVO 1TB NVMe SSD NVMe 1 TB S7M3NS0X519990K

Storage Controller / HBA#

Field Details
Manufacturer HPE
Model Smart Array P408i-a SR Gen10
Serial number
Firmware
Controller mode
Cache size
Cache protection
Connected backplane

PCIe Expansion Cards#

Physical slot Device type Manufacturer Model Part number Serial number PCIe generation/width Notes
Embedded video Video adapter Matrox MGA G200eH3
Embedded storage Storage controller HPE Smart Array P408i-a SR Gen10
PCIe Slot 2 NVMe controller Samsung NVM Express Controller

Network Hardware#

Port/interface Manufacturer Model MAC address Speed Serial number Notes
Embedded FlexibleLOM port 1 HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter 94:57:A5:65:7E:88 10 GbE
Embedded FlexibleLOM port 2 HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter 94:57:A5:65:7E:8C 10 GbE

Power Supplies#

Position Manufacturer Model Wattage Serial number Redundant configuration Notes
PSU 1 HPE 865408-B21 500 W 5WBXH0E4DCDAFZ Redundant Present, OK; hot-replaceable
PSU 2 HPE 865408-B21 500 W 5WBXK0ELLC1EYL Redundant Present, OK; hot-replaceable

Cooling and Thermal Hardware#

Component Manufacturer Model Serial number Notes
Fan assembly HPE System fan assembly, 7 fans Redundant; iLO reports OK

Included Accessories#

Item Manufacturer/model Serial number Quantity Notes
Rack rails HPE 1
Drive caddies HPE 8
Power cables HPE 1
Network cables iLO Monoprice 1 3m
Network cables 1Gbe Monoprice 1 3m
Network cables 10Gbe Ubiquiti 1 3m - SFP+

Other Physical Devices#

Device Manufacturer/model Serial number Notes
Smart Storage Energy Pack HPE 875241-B21 6WQXK0FWYCY4NB 96 W; firmware 0.70

Insurance Valuation#

Field Details
Replacement description
Replacement value
Valuation currency
Valuation date
Equivalent current model
Special considerations

Notes#

  • iLO reports Advanced ECC / A3DC memory protection and 24 populated 32 GiB RDIMMs (768 GiB total).
  • iLO reports two 500 W redundant HPE power supplies and a Smart Storage Energy Pack.
  • No hardware test was run.

HP3 - HPE DL360 Gen10

HP3 - HPE DL360 Gen10#

Asset Summary#

Field Details
Manufacturer HPE
Model DL360 Gen10
Hostname HP3Proxmox
Management address 10.1.1.13
iLO address 10.1.5.13
iLO hostname HP3-iLO
iLO firmware 3.15 (2025-08-11)
Serial number MXQ93601H1
Product number 867958-B21
Physical location House Mechanical Room

Server Chassis#

Field Details
Form factor Rack-mount server
Rack height 1U
Chassis configuration HPE ProLiant DL360 Gen10
System board HPE ProLiant DL360 Gen10; board serial PWUFL0ARHCF663
Drive-bay configuration
Rail kit HP rails
Other chassis components

Processors#

Socket Manufacturer Model Cores Threads Speed Serial/identifier Notes
CPU 1 Intel Xeon Silver 4214 12 24 2.20 GHz
CPU 2 Intel Xeon Silver 4214 12 24 2.20 GHz

Memory#

Slot Manufacturer Part number Type Capacity Speed ECC Serial number Notes
PROC 1 DIMM 1 RDIMM 16 GiB 2400 MHz ECC
PROC 1 DIMM 2 RDIMM 16 GiB 2400 MHz ECC
PROC 1 DIMM 3 RDIMM 16 GiB 2400 MHz ECC
PROC 1 DIMM 4 RDIMM 32 GiB 2400 MHz ECC
PROC 1 DIMM 5 RDIMM 16 GiB 2400 MHz ECC
PROC 1 DIMM 6 RDIMM 16 GiB 2400 MHz ECC
PROC 1 DIMM 7 RDIMM 32 GiB 2400 MHz ECC
PROC 1 DIMM 8 RDIMM 16 GiB 2400 MHz ECC
PROC 1 DIMM 9 RDIMM 32 GiB 2400 MHz ECC
PROC 1 DIMM 10 RDIMM 16 GiB 2400 MHz ECC
PROC 1 DIMM 11 RDIMM 32 GiB 2400 MHz ECC
PROC 1 DIMM 12 RDIMM 16 GiB 2400 MHz ECC
PROC 2 DIMM 1 RDIMM 16 GiB 2400 MHz ECC
PROC 2 DIMM 2 RDIMM 32 GiB 2400 MHz ECC
PROC 2 DIMM 3 RDIMM 16 GiB 2400 MHz ECC
PROC 2 DIMM 4 RDIMM 32 GiB 2400 MHz ECC
PROC 2 DIMM 5 RDIMM 16 GiB 2400 MHz ECC
PROC 2 DIMM 6 RDIMM 32 GiB 2400 MHz ECC
PROC 2 DIMM 7 RDIMM 16 GiB 2400 MHz ECC
PROC 2 DIMM 8 RDIMM 16 GiB 2400 MHz ECC
PROC 2 DIMM 9 RDIMM 32 GiB 2400 MHz ECC
PROC 2 DIMM 10 RDIMM 16 GiB 2400 MHz ECC
PROC 2 DIMM 11 RDIMM 16 GiB 2400 MHz ECC
PROC 2 DIMM 12 RDIMM 16 GiB 2400 MHz ECC

Total installed memory: 512 GiB Memory protection: Advanced ECC Memory details: DDR4 registered ECC RDIMM, 2400 MHz configured, 72-bit total width / 64-bit data width, 1.2 V. Manufacturer, part number, and module serial numbers are not exposed.

HP4 - HPE DL360 Gen9

HP4 - HPE DL360 Gen9#

Asset Summary#

Field Details
Manufacturer HPE
Model DL360 Gen9
Hostname HP4Proxmox
Management address 10.1.1.14
iLO address 10.1.5.14
iLO hostname HP4-iLO
iLO firmware 2.82 (2023-02-06)
Serial number MXQ530009P
Product number 755258-B21
Physical location Server Rack

Server Chassis#

Field Details
Form factor Rack-mount server
Rack height 1U
Chassis configuration HPE ProLiant DL360 Gen9
System board HPE ProLiant DL360 Gen9; board serial MXQ530009P
Drive-bay configuration SFF; 8 bays, 4 internal drives populated
Rail kit HP rails
Other chassis components

Processors#

Socket Manufacturer Model Cores Threads Speed Serial/identifier Notes
CPU 1 Intel Xeon E5-2620 v3 6 12 2.40 GHz
CPU 2

Memory#

Slot Manufacturer Part number Type Capacity Speed ECC Serial number Notes
PROC 1 DIMM 1 RDIMM 16 GiB 1866 MHz ECC 1-rank
PROC 1 DIMM 4 RDIMM 16 GiB 1866 MHz ECC 1-rank
PROC 1 DIMM 9 RDIMM 16 GiB 1866 MHz ECC 1-rank
PROC 1 DIMM 12 RDIMM 16 GiB 1866 MHz ECC 1-rank

Total installed memory: 64 GiB

HP5 - HPE DL360 Gen9

HP5 - HPE DL360 Gen9#

Asset Summary#

Field Details
Manufacturer HPE
Model
Hostname HP5Proxmox
Management address 10.1.1.15
Serial number
Physical location Server Rack

Server Chassis#

Field Details
Form factor
Rack height
Chassis configuration
System board
Drive-bay configuration
Rail kit
Other chassis components

Processors#

Socket Manufacturer Model Cores Threads Speed Serial/identifier Notes
CPU 1
CPU 2

Memory#

Slot Manufacturer Part number Type Capacity Speed ECC Serial number Notes

Storage Drives#

Bay/slot Manufacturer Model Drive type Interface Capacity Serial number Firmware Notes

Storage Controller / HBA#

Field Details
Manufacturer
Model
Serial number
Firmware
Controller mode
Cache size
Cache protection
Connected backplane

PCIe Expansion Cards#

Physical slot Device type Manufacturer Model Part number Serial number PCIe generation/width Notes

Network Hardware#

Port/interface Manufacturer Model MAC address Speed Serial number Notes

Power Supplies#

Position Manufacturer Model Wattage Serial number Redundant configuration Notes
PSU 1
PSU 2

Cooling and Thermal Hardware#

Component Manufacturer Model Serial number Notes
Fan assembly

Included Accessories#

Item Manufacturer/model Serial number Notes
Rack rails
Drive caddies
Power cables
Other

Other Physical Devices#

Device Manufacturer/model Serial number Notes

Insurance Valuation#

Field Details
Replacement description
Replacement value
Valuation currency
Valuation date
Equivalent current model
Special considerations

Notes#

  • Hardware details are intentionally blank pending a later audit.
  • No server connection or hardware test was performed while the server was powered off.

HP7 - HPE DL360 Gen10

HP7 - HPE DL360 Gen10#

Asset Summary#

Field Details
Manufacturer HPE
Model DL360 Gen10
Hostname HP7Proxmox
FQDN HP7.proxmox
Management address 10.1.1.17
iLO address 10.1.5.17
iLO hostname HP7-iLO
iLO firmware 3.15 (2025-08-11)
Serial number MXQ93700SD
Product number 867958-B21
Physical location Garage

Server Chassis#

Field Details
Form factor Rack-mount server
Rack height 1U
Chassis configuration HPE ProLiant DL360 Gen10
System board HPE ProLiant DL360 Gen10; board serial PWUFL0ARHC957L
Drive-bay configuration
Rail kit HP rails
Other chassis components

Processors#

Socket Manufacturer Model Cores Threads Speed Serial/identifier Notes
CPU 1 Intel Xeon Gold 6138 20 40 2.00 GHz
CPU 2 Intel Xeon Gold 6138 20 40 2.00 GHz

Memory#

Slot Manufacturer Part number Type Capacity Speed ECC Serial number Notes
PROC 1 DIMM 1 HPE P03050-091 RDIMM 16 GiB 2400 MHz ECC
PROC 1 DIMM 3 HPE P03050-091 RDIMM 16 GiB 2400 MHz ECC
PROC 1 DIMM 5 HPE P03050-091 RDIMM 16 GiB 2400 MHz ECC
PROC 1 DIMM 8 HPE P03050-091 RDIMM 16 GiB 2400 MHz ECC
PROC 1 DIMM 10 HPE P03050-091 RDIMM 16 GiB 2400 MHz ECC
PROC 1 DIMM 12 RDIMM 16 GiB 2400 MHz ECC
PROC 2 DIMM 1 RDIMM 16 GiB 2400 MHz ECC
PROC 2 DIMM 3 RDIMM 16 GiB 2400 MHz ECC
PROC 2 DIMM 5 HPE P03050-091 RDIMM 16 GiB 2400 MHz ECC
PROC 2 DIMM 8 RDIMM 16 GiB 2400 MHz ECC
PROC 2 DIMM 10 HPE P03050-091 RDIMM 16 GiB 2400 MHz ECC
PROC 2 DIMM 12 HPE P03050-091 RDIMM 16 GiB 2400 MHz ECC

Total installed memory: 192 GiB Memory protection: Advanced ECC Memory details: DDR4 registered ECC RDIMM, 2400 MHz configured. Module serial numbers are not exposed.